Temperature Sensors
SITRANS TS-Temperature Sensors are the perfect basis for precise and safe temperature measurement. The RTDs and Thermocouples support a broad range of application through the process industries.
- SITRANS TS100: with direct connected cable
- SITRANS TS200: with direct mount connectors (M12, Lemo, …)
- SITRANS TS300: for food, pharmaceuticals and biotechnology modular design
- SITRANS TS500: The industry-grade temperature sensor supports a wide range of measuring go from basic applications to solutions in harsh environment.
- SITRANS TS Inserts: spare part for the SITRANS TS500 or as component to build up complete temperature assemblies
- SITRANS TSthermowell: a comprehensive portfolio of thermowells
- The thermocouples are available in versions up to 1250 °C and and are suitable for the mounting of SITRANS TH320, SITRANS TH420, SITRANS TH400
- The thermoresistors are available for flue gas and for damp rooms (mounting possible for SITRANS TH100, SITRANS TH320, SITRANS TH420, SITRANS TH400)
SITRANS TS100
Benifits
-
Simple mounting – Compression fittings or soldering nipples enable a fast commissioning
-
Universal – Sensor line is designed to serve a wide range of applications
-
Customizable – SITRANS TS100 is based on a modular platform offering variety
- Safe solution – Explosion protection by intrinsically safety Ex i (IS) even in Zone 0
- Certificates for major markets
Detail
Output |
Sensor signal |
---|---|
Max. operation temperature – cable end |
Pt 100 Basic: -50 .. .+400 °C (-58 … +752 °F) Pt 100 Extended: -196 … +600 °C (-320.8 … +1112 °F) Thermo couple -40 … +1250 °C (-40 … 2282 °F) Depending on type -40° … +80 °C (-40 … +176 °F) |
Ingress protection |
IP66 (between sensor and cable) |
Approvals |
ATEX, IECEx, cCSAus, EAC, NEPSI |
SITRANS TS200
Benifits
- Simple mounting – Compression fittings or soldering nipples enable a fast commissioning
- Universal – Sensor line is designed to serve a wide range of applications
- Customizable – SITRANS TS200 is based on a modular platform offering variety
- Safe solution – Explosion protection by intrinsically safety Ex i (IS) even in Zone 0
- Certificates for major markets
Detail
Output |
direct sensor signal |
---|---|
Max. operaton temperature – measuring point – cable end |
Pt 100 Basic: – 50 … +400 °C (-58 … +752 °F) -40 … +80 °C (-40 … +176 °F) |
Ingress protection |
IP54 (depending on connector type) |
Approvals |
ATEX, IECEx, CSA, cCSAus, NEPSI, EAC, EACEx |
SITRANS TS300
Benifits
- Hygienic – Sensor design according to EHEDG recommendations
- Available – Inserts exchangeable
- Low costs, many advantages – Low cost of ownership for installation, validation and recalibration; no process disturbance
Detail
Output |
direct sensor signal PA (TH400) |
---|---|
Max. operation temperature |
–30…+300 °C |
Ingress Protection |
IP65 (IP54 for some type of connection heads) |
SITRANS TS500
Benifits
-
Exchangeable during operation
-
Wide application range due to modular design
- Explosion protection by the ignition protection types, intrinsically safe Ex i (IS), increased safety Ex e (NI) or flameproof enclosure Ex d (XP) resp dust protection by means of enclosure Ex t (DIP)
- Certificates for major markets
-
With optional local indicator and operation
Detail
Output |
direct sensor signal 4…20 mA (TH100/TH320) HART (TH320) PA (TH420) FF (TH420) |
---|---|
Max. operation temperature – measuring point:
– connection head: |
Pt 100 Basic: –50 … +400 °C (-58 … +752 °F) -40 … +100 °C (+85 °C with transmitter) |
Ingress protection |
IP54-68, depending on the type of connection head and cable gland |
Approvals |
General Purpose (FM, CSA) for use in hazardous locations ATEX, IECEx, cCSAus, NEPSI, EAC, KOSHA for use in marine applications DNV |